A tall Kiturami controller with three icon buttons on the left (목욕, 설정, 선택), arrows and power on the right, and a narrow screen in the middle.
각 버튼은 무슨 기능인가요?
1Bath · 목욕mogyokExtra hot water for a bath; returns to the previous mode after 2 h 30 min.
2Set (water temps) · 설정seoljeongPress once: radiator water temp bar flashes. In bath mode: sets bath water temp (41–85°C). Change with the arrows.
3Select mode · 선택seontaekEach press: 실내 (room) → 예약 (timer) → 외출 (away) → 실내. Also confirms a setting.
4Screen · 표시창pyosichangWanted temp, current temp, timer, water-temp bar and mode icons. Backlight switches off after ~10 s (blank screen in this photo is normal).
5Running light · 운전표시unjeon pyosiSmall light at the top: on when the boiler is allowed to run.
6Up · 올림ollimRaises the wanted temp / flashing value. In 예약 mode it opens one of the timer values.
7Down · 내림naerimLowers the value. In 예약 mode it opens the other timer value.
8Power · 전원jeonwonTurns the controller and boiler off/on.
어떤 설정이 좋나요?
Winter: 실내 at 21–22°C, water bar at 4–5 blocks (초겨울 80°C / 겨울 85°C). Away: 외출.
어떻게 하나요?
켜기
1Press 전원 (bottom right). Touch any button to wake the screen backlight.
실내 온도 맞추기
1Press 선택 until the screen shows 실내.
2Press ▲/▼ to set the wanted temp to 22.
3Press 선택 or wait — it saves automatically.
며칠 집 비울 때
1Press 선택 until 외출 shows.
2Keep power on. In deep cold set 실내 to 10–15°C instead (manual advice).
예약 설정
1Press 선택 until 예약 shows.
2Press ▲: one timer value flashes — set with ▲/▼.
3Press ▼: the other value flashes — set with ▲/▼.
4The pair is run-minutes + rest-hours. Manual example: 20 min on, 2 h off, repeating.
5Press 선택 or wait to save.
온수만 (여름)
1No dedicated hot-water-only mode in the manual.
2Use 외출 in summer — heating only runs to prevent freezing (taps still give hot water on Kiturami boilers — see notes).
온수 온도 바꾸기
1Press 목욕, then press 설정: bath temp flashes.
2Set with ▲/▼ (41–85°C). Press 선택 or wait to save.
끄기
1Press 전원. In winter use 외출 instead.
화면 글자는 무슨 뜻인가요?
실내 (sun icon)
Room mode
Heats to the wanted room temp.
예약 (clock icon)
Timer
Runs minutes / rests hours, repeating.
외출 (suitcase icon)
Away
Frost protection only.
목욕 (shower icon)
Bath
Extra hot water, 2 h 30 min.
희망온도 / 현재온도
Wanted / current temp
Top number = wanted; middle = current room temp.
bar of 1–5 blocks
Radiator water temp
1 = 여름 50°C … 5 = 겨울 85°C.
1588-9000
Service
Shown with error codes.
이 모델에서 자주 헷갈리는 점
The screen goes dark after about 10 s — press a button to wake it before reading.
This flat uses several controllers on one wall (photo 29 also has a separate Kotech room thermostat on the right). The Kiturami one runs the boiler; the other controls a room/zone. Changing only one may not heat the room you are in.
In 예약 mode the ▲ and ▼ arrows open the two timer values instead of changing room temp.
에러가 떠요
Errors flash on the screen as 'Er' plus a number, and the screen may also show 'A/S 문의는 1588-9000'. From the older Kiturami (CTR-5700PLUS) manual: Er 01 = burner did not light, Er 03 = flame went out (check the gas valve is open), Er 95 = low water (refill/pressure), Er 96 = overheat, Er 97 = gas leak detected (open windows, do not use switches, call). Press 전원 (power) off/on to restart — it only allows 3 restarts in a row, then wait 5 minutes. If it comes back, call 1588-9000.