Daesung Celtic DR-240 ์˜์–ด ์„ค๋ช…

A simple Daesung wall controller: four round buttons pick the mode and one big centre dial sets the temperature or timer.

๊ฐ ๋ฒ„ํŠผ์€ ๋ฌด์Šจ ๊ธฐ๋Šฅ์ธ๊ฐ€์š”?

์„œ์šธ ์ง‘์˜ Daesung Celtic DR-240 ๋ณด์ผ๋Ÿฌ ์กฐ์ ˆ๊ธฐ
  1. 1Running lamp ยท ๊ฐ€๋™ ๋žจํ”„gadong raempeuThe small dot next to the drop icon. The manual says a running lamp turns on when the boiler is actually heating.
  2. 2Display ยท ํ‘œ์‹œ์ฐฝpyosichangShows the temperature setting, 'ot' in Away mode, or hours (e.g. 6h) in timer mode.
  3. 3Power ยท ์ „์›jeonwonTurns the controller on. Pressing again turns the display off and stops heating and hot water.
  4. 4Mode lamps ยท ์‹ค์˜จยท์˜จ๋Œ ๋žจํ”„sironยทondol raempeuTwo small lamps above the button. One lights for room-air (์‹ค์˜จ) mode, the other for floor (์˜จ๋Œ) mode.
  5. 5Room / Floor heating ยท ์‹ค์˜จยท์˜จ๋ŒsironยทondolSwitches between room-air mode (set 10โ€“40ยฐC) and floor-water mode (set 50โ€“80ยฐC). Also cancels Away and Hot-water-only.
  6. 6Hot water only ยท ์˜จ์ˆ˜์ „์šฉonsu jeonyongHeating off, hot water only. The dial then sets tap-water temperature.
  7. 7Dial ยท ๋‹ค์ด์–ผ (โˆ’/+)daieolTurn right (+) to raise, left (โˆ’) to lower whatever the current mode sets: temperature, hot-water temperature or timer hours. It saves by itself after a moment.
  8. 8Timer heating ยท ์˜ˆ์•ฝ๋‚œ๋ฐฉyeyak nanbangRepeating timer: heats 20 minutes, pauses 1โ€“6 hours (set with the dial), repeats.
  9. 9Away ยท ์™ธ์ถœoechulStops heating while you are out. Display shows 'ot'. Press ์‹ค์˜จยท์˜จ๋Œ to cancel.
  10. 10Service number ยท A/S 1588-8577ei-eseuDaesung customer service / repair line.

์–ด๋–ค ์„ค์ •์ด ์ข‹๋‚˜์š”?

Floor mode (์˜จ๋Œ) at 60ยฐC while you are home; ์˜ˆ์•ฝ๋‚œ๋ฐฉ at 3h when out for the day in winter; hot water 45ยฐC. Daesung's own manual recommends floor mode over room mode because room mode is easily fooled by drafts and ventilation.

์–ด๋–ป๊ฒŒ ํ•˜๋‚˜์š”?

์ผœ๊ธฐ

  1. 1Press ์ „์› (top right). The display lights up.

์‹ค๋‚ด ์˜จ๋„ ๋งž์ถ”๊ธฐ

  1. 1Press ์‹ค์˜จยท์˜จ๋Œ until the display shows a setting between 10 and 40 (room-air mode).
  2. 2Turn the dial to 22.
  3. 3Leave it. It saves after a moment and heats whenever the room is below 22ยฐC.

์˜จ๋Œ ๋ชจ๋“œ

  1. 1Press ์‹ค์˜จยท์˜จ๋Œ until the display shows a setting between 50 and 80 (floor mode).
  2. 2Turn the dial to 60.
  3. 3Leave it. The boiler keeps the floor-pipe water at 60ยฐC.

๋ฉฐ์น  ์ง‘ ๋น„์šธ ๋•Œ

  1. 1Press ์™ธ์ถœ (bottom right). Its lamp lights and the display shows 'ot'.
  2. 2When you are back, press ์‹ค์˜จยท์˜จ๋Œ to return to heating.

์˜ˆ์•ฝ ์„ค์ •

  1. 1Press ์˜ˆ์•ฝ๋‚œ๋ฐฉ (bottom left). Its lamp lights and the display shows hours, e.g. 3h.
  2. 2Turn the dial to choose the pause: 1h to 6h.
  3. 3The boiler heats for 20 minutes, pauses for that many hours, and repeats.

์˜จ์ˆ˜๋งŒ (์—ฌ๋ฆ„)

  1. 1Press ์˜จ์ˆ˜์ „์šฉ (middle right). Its lamp lights.
  2. 2Heating is now off; hot water still works.

์˜จ์ˆ˜ ์˜จ๋„ ๋ฐ”๊พธ๊ธฐ

  1. 1Press ์˜จ์ˆ˜์ „์šฉ.
  2. 2Turn the dial: 37โ€“45ยฐC in 1ยฐC steps, 45โ€“60ยฐC in 5ยฐC steps. 45 is comfortable for showers.
  3. 3Press ์‹ค์˜จยท์˜จ๋Œ afterwards if you want heating back โ€” ์˜จ์ˆ˜์ „์šฉ keeps heating off.

๋„๊ธฐ

  1. 1Press ์ „์›. The display goes dark and heating and hot water stop.

ํ™”๋ฉด ๊ธ€์ž๋Š” ๋ฌด์Šจ ๋œป์ธ๊ฐ€์š”?

otAwayAway (์™ธ์ถœ) mode is on. No heating.
1hโ€“6hTimer hoursTimer heating gap shown while ์˜ˆ์•ฝ๋‚œ๋ฐฉ is active.
Hi / LoHigh / LowHot-water setting on the DR-240(S) version, which only has high/low instead of degrees.
๊ฐ€๋™ ๋žจํ”„ (red dot)RunningBoiler is firing to reach your setting.

์ด ๋ชจ๋ธ์—์„œ ์ž์ฃผ ํ—ท๊ฐˆ๋ฆฌ๋Š” ์ 

  • After using ์˜จ์ˆ˜์ „์šฉ the heating stays OFF until you press ์‹ค์˜จยท์˜จ๋Œ again.
  • To stop heating in room mode, set the dial below the current room temperature.
  • DR-240 and DR-240N look identical but use different boiler wiring โ€” they are not interchangeable if you replace one.
  • Hidden setting (user blog, not in the manual): hold ์˜ˆ์•ฝ๋‚œ๋ฐฉ about 5 s to change the 20-minute timer run time (5โ€“55 min).
  • Don't switch off with ์ „์› in deep winter; use ์™ธ์ถœ or the timer. Daesung boilers have built-in freeze protection (pipe water at 7ยฐC or below triggers a run up to 40ยฐC), but only while the boiler is plugged in and the gas valve is open.

์—๋Ÿฌ๊ฐ€ ๋– ์š”

Error codes show on the display. Codes for this model were not sourced โ€” note the code and call 1588-8577.

A/S: 1588-8577

์„œ์šธ ์ง‘์˜ Daesung Celtic DR-240 ๋ณด์ผ๋Ÿฌ ์กฐ์ ˆ๊ธฐ์„œ์šธ ์ง‘์˜ Daesung Celtic DR-240 ๋ณด์ผ๋Ÿฌ ์กฐ์ ˆ๊ธฐ

๋‹ค๋ฅธ Daesung Celtic ์กฐ์ ˆ๊ธฐ

ํ•œ๊ตญ ๋‚œ๋ฐฉ ๊ฐ€์ด๋“œ ์ „์ฒด ๋ณด๊ธฐ โ†’

์šฐ๋ฆฌ ์ง‘ ๋ณด์ผ๋Ÿฌ๊ฐ€ ์—†๋‚˜์š”?

์‚ฌ์ง„ ํ•œ ์žฅ์„ ๋ณด๋‚ด์ฃผ์‹œ๋ฉด ์˜์–ด๋กœ ์„ค๋ช…ํ•ด ๋“œ๋ ค์š”.

๋ณด๋‚ด์‹œ๋ฉด ๊ฐœ์ธ์ •๋ณด์ฒ˜๋ฆฌ๋ฐฉ์นจ์— ๋™์˜ํ•˜๋Š” ๊ฒƒ์œผ๋กœ ๋ด…๋‹ˆ๋‹ค.